Name: Electric Junction
Display Field: subnetworkname
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Copyright Text:
Min. Scale: 0
Max. Scale: 0
Default Visibility: false
Max Record Count: 2000
Supported query Formats: JSON, geoJSON, PBF
Use Standardized Queries: True
Extent:
XMin: 502997.6221
YMin: 5447117.8223
XMax: 508499.65
YMax: 5453868.4173
Spatial Reference: 26910 (26910)
Drawing Info:
{"renderer":{"type":"uniqueValue","field1":"ASSETGROUP","uniqueValueGroups":[{"heading":"ASSETGROUP","classes":[{"label":"Medium Voltage Attachment","description":"Medium Voltage Attachment","symbol":{"type":"esriSMS","style":"esriSMSCircle","color":[239,252,184,255],"size":4,"angle":0,"xoffset":0,"yoffset":0,"outline":{"color":[0,0,0,255],"width":0.7}},"values":[["7"]]},{"label":"Medium Voltage Connection Point","description":"Medium Voltage Connection Point","symbol":{"type":"esriSMS","style":"esriSMSCircle","color":[179,223,252,255],"size":4,"angle":0,"xoffset":0,"yoffset":0,"outline":{"color":[0,0,0,255],"width":0.7}},"values":[["8"]]},{"label":"Medium Voltage Line End","description":"Medium Voltage Line End","symbol":{"type":"esriSMS","style":"esriSMSCircle","color":[252,217,212,255],"size":4,"angle":0,"xoffset":0,"yoffset":0,"outline":{"color":[0,0,0,255],"width":0.7}},"values":[["9"]]}]}],"uniqueValueInfos":[{"symbol":{"type":"esriSMS","style":"esriSMSCircle","color":[239,252,184,255],"size":4,"angle":0,"xoffset":0,"yoffset":0,"outline":{"color":[0,0,0,255],"width":0.7}},"value":"7","label":"Medium Voltage Attachment"},{"symbol":{"type":"esriSMS","style":"esriSMSCircle","color":[179,223,252,255],"size":4,"angle":0,"xoffset":0,"yoffset":0,"outline":{"color":[0,0,0,255],"width":0.7}},"value":"8","label":"Medium Voltage Connection Point"},{"symbol":{"type":"esriSMS","style":"esriSMSCircle","color":[252,217,212,255],"size":4,"angle":0,"xoffset":0,"yoffset":0,"outline":{"color":[0,0,0,255],"width":0.7}},"value":"9","label":"Medium Voltage Line End"}],"fieldDelimiter":",","authoringInfo":{"colorRamp":{"type":"multipart","colorRamps":[{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[231,197,252,255],"toColor":[231,197,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[193,252,187,255],"toColor":[193,252,187,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,212,182,255],"toColor":[252,212,182,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[187,246,252,255],"toColor":[187,246,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,179,194,255],"toColor":[252,179,194,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[187,213,252,255],"toColor":[187,213,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[240,252,215,255],"toColor":[240,252,215,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[189,252,224,255],"toColor":[189,252,224,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[240,252,179,255],"toColor":[240,252,179,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,212,234,255],"toColor":[252,212,234,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[179,184,252,255],"toColor":[179,184,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,217,212,255],"toColor":[252,217,212,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,179,244,255],"toColor":[252,179,244,255]}]}}},"scaleSymbols":true,"transparency":0,"labelingInfo":null}
HasZ: true
HasM: true
Has Attachments: false
Has Geometry Properties: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Object ID Field: OBJECTID
Unique ID Field:
IsSystemMaintained : True
Global ID Field: GLOBALID
Type ID Field: ASSETGROUP
Fields:
- OBJECTID (type: esriFieldTypeOID, alias: OBJECTID, SQL Type: sqlTypeOther, length: 0, nullable: false, editable: false)
- ASSETGROUP (type: esriFieldTypeInteger, alias: Asset group, SQL Type: sqlTypeOther, nullable: false, editable: true)
- ASSETTYPE (type: esriFieldTypeSmallInteger, alias: Asset type, SQL Type: sqlTypeOther, nullable: false, editable: true)
- GLOBALID (type: esriFieldTypeGlobalID, alias: Global ID, SQL Type: sqlTypeOther, length: 38, nullable: false, editable: false)
- SUBNETWORKNAME (type: esriFieldTypeString, alias: Subnetwork name, SQL Type: sqlTypeOther, length: 2000, nullable: false, editable: true)
- SUPPORTEDSUBNETWORKNAME (type: esriFieldTypeString, alias: Supported subnetwork name, SQL Type: sqlTypeOther, length: 2000, nullable: false, editable: true)
- assetid (type: esriFieldTypeString, alias: assetid: Asset Identifier, SQL Type: sqlTypeOther, length: 64, nullable: true, editable: true)
- phasesenergized (type: esriFieldTypeSmallInteger, alias: phasesenergized: Phases Propagated, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: DeEnergized], [1: C], [2: B], ... 5 more ...)
- installdate (type: esriFieldTypeDate, alias: installdate: Date Installed, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- notes (type: esriFieldTypeString, alias: notes: General Notes, SQL Type: sqlTypeOther, length: 2000, nullable: true, editable: true)
- ownedby (type: esriFieldTypeSmallInteger, alias: ownedby: Owned by, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: City], [2: Private], ... 6 more ...)
- maxvoltage (type: esriFieldTypeInteger, alias: maxvoltage: Maximum Operating Voltage (L-L), SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [208: 208 V], [240: 240 V], ... 32 more ...)
- phasescurrent (type: esriFieldTypeSmallInteger, alias: phasescurrent: User Assigned Phases, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: DeEnergized], [1: C], [2: B], ... 5 more ...)
- lifecyclestatus (type: esriFieldTypeSmallInteger, alias: lifecyclestatus: Lifecycle Status, SQL Type: sqlTypeOther, nullable: false, editable: true, Coded Values: [0: Unknown], [1: Proposed], [2: Approved], ... 15 more ...)
Types:
ID: 7
Name: Medium Voltage Attachment
Domains:
- Field Name: ASSETTYPE
Coded Values:[0: Unknown], [60: Overhead], [61: Underground]
- Field Name: phasesenergized
Inherited
- Field Name: ownedby
Inherited
- Field Name: maxvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: phasescurrent
Inherited
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
Templates:
Name: Medium Voltage Attachment
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- ASSETGROUP: 7
- ASSETTYPE: 0
- lifecyclestatus: 8
- SUBNETWORKNAME: Unknown
- SUPPORTEDSUBNETWORKNAME: Unknown
- phasesenergized: 0
- ownedby: 1
ID: 8
Name: Medium Voltage Connection Point
Domains:
- Field Name: ASSETTYPE
Coded Values:[0: Unknown], [80: Busbar Tap], [81: Overhead Splice], More
- Field Name: phasesenergized
Inherited
- Field Name: ownedby
Inherited
- Field Name: maxvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: phasescurrent
Inherited
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
Templates:
Name: Medium Voltage Connection Point
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- ASSETGROUP: 8
- ASSETTYPE: 0
- lifecyclestatus: 8
- SUBNETWORKNAME: Unknown
- SUPPORTEDSUBNETWORKNAME: Unknown
- phasesenergized: 0
- ownedby: 1
ID: 9
Name: Medium Voltage Line End
Domains:
- Field Name: ASSETTYPE
Coded Values:[0: Unknown], [100: Overhead Line End], [101: Underground Terminator], More
- Field Name: phasesenergized
Inherited
- Field Name: ownedby
Inherited
- Field Name: maxvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: phasescurrent
Inherited
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
Templates:
Name: Medium Voltage Line End
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- ASSETGROUP: 9
- ASSETTYPE: 0
- lifecyclestatus: 8
- SUBNETWORKNAME: Unknown
- SUPPORTEDSUBNETWORKNAME: Unknown
- phasesenergized: 0
- ownedby: 1
Is Data Versioned: false
Has Contingent Values: false
Supports Rollback On Failure Parameter: true
Last Edit Date: 10/2/2026 10:44:48 PM
Schema Last Edit Date: 10/2/2026 10:44:48 PM
Data Last Edit Date: 10/2/2026 10:44:48 PM
Supported Operations:
Query
Query Pivot
Query Top Features
Query Analytic
Query Bins
Generate Renderer
Validate SQL
Get Estimates
ConvertFormat